PG [v50]
Profile Details:
Front thickness from the inside
Profile depth about
Clamping depth
Clamping thickness standard
Integrated fitting technique made of stainless steel
Lamella height:
Element sizes:
Opening angle:
Inspections:
Tightness during driving rain according to EN 12208
Air tightness according to EN 12207
Wind load according to EN 12210
Sound protection Rw
Natural smoke and heat exhaust ventilators according to EN 12101-2
50 mm
120 mm
18 mm
24, 32, 37 mm
Yes
From 250 mm to 700 mm
Wide AK frames at least from 450 mm to max. 5.000 mm
Depending on the lamella height ranging up to 85 degrees.
Up to E 2100
Class 4
Class C3/B3
40 dB with standard glazing
44 dB with sound insulation glass
Yes
1 - 14
<
>
© 2019 mp2 GmbH | Im Bächel 1 | 66885 Altenglan | Germany | Phone: +49 6381 929959-0 | Fax: +49 6381 929959-9
info@mpzwei.de | www.mpzwei.de